September 2015

Conference Paper

Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR

By:
Guinn, I.; Abgrall, N.; Avignone, III, F.; Bertrand, F.; Efremenko, Yuri; Galindo-Uribarri, A; Green, M.; Radford, D.; Romero-Romero, E.; Varner, R.; White, B.; Wilkerson, J.; Yu, C.-H.; Majorana,
Journal Name:
Journal of Physics: Conference Series
Page Number:
012009-012009-5
Volume:
606
Issue Number:
N/A
Publication Date:
September 2015
Conference Name:
2nd Workshop on Germanium Detectors and Technologies
Conference Location:
Vermillion, South Dakota, United States of America
Conference Sponsor:
NSF, South Dakota Governor's Office Economic Development, S. Dakota Board of Regents, Univ. SD
View DOI Listing:
https://doi.org/10.1088/1742-6596/606/1/012009

Abstract

The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay (0 nu beta beta) in Ge-76. Such an experiment would require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the beta beta decay. Designing low-noise electronics, which must be placed in close proximity to the detectors, presents a challenge to reaching this background target. This paper will discuss the MAJORANA collaboration's solutions to some of these challenges.