September 2011

Conference Paper

Justification for an Increase in Authorized Operating Power at HFIR

By:
Primm Iii, Roy T; Procop, Germina
Publication Date:
September 2011
Conference Name:
2011 Annual Meeting of the American Nuclear Society
Conference Location:
Hollywood, Florida, United States of America

Abstract

1) Using verified and validated reactor physics methods coupled to a currently accepted thermal hydraulic analysis methodology, onset of incipient boiling power agrees well with the currently-accepted safety basis value. The MCNP-based methodology is acceptable for scoping studies of LEU fuel conversion. 2) A balance-of-plant assessment would have to be conducted to determine if the power up-rate to 100 MW could be supported for LEU fuel. 3) While analyses performed 45 years ago have been shown to be in agreement with today’s methods, there is an advantage to the current methodology in that people working at HFIR today can explain/justify/defend the safety analyses rather than relying solely on documentation.