July 2014

Conference Paper

J-R Curve Determination for Disk-shaped Compact Specimens Based on the Normalization Method and Direct Current Potential Drop Technique

By:
Chen, Xiang ; Nanstad, Randy K; Sokolov, Mikhail A
Page Number:
70-87
Volume:
6th
Book Title:
Small
Publication Date:
July 2014
Publisher Location:
ASTM International, West Conshohocken, Pennsylvania, United States of America
Conference Name:
ASTM Sixth International Symposium on Small Specimen Test Techniques
Conference Location:
Houston, Texas, United States of America
Conference Sponsor:
ASTM
View DOI Listing:
https://doi.org/10.1520/STP157620140012

Abstract

Material ductile fracture toughness can be described by J-integral versus crack extension relationship (J-R curve). As a conventional J-R curve measurement method, unloading compliance (UC) becomes impractical in elevated temperature testing due to relaxation of the material and a friction induced back-up shape of the J-R curve. In addition, the UC method may underpredict the crack extension for standard disk-shaped compact (DC(T)) specimens. In order to address these issues, the normalization method and direct current potential drop (DCPD) technique were applied for determining J-R curves at 24°C and 500°C for 0.18T DC(T) specimens made from type 316L stainless steel. For comparison purchase, the UC method was also applied in 24°C tests. The normalization method was able to yield valid J-R curves in all tests. The J-R curves from the DCPD technique need adjustment to account for the potential drop induced by plastic deformation, crack blunting, etc. and after applying a newly-developed DCPD adjustment procedure, the post-adjusted DCPD J-R curves essentially matched J-R curves from the normalization method. In contrast, the UC method underpredicted the crack extension in all tests resulting in substantial deviation in the derived J-R curves manifested by high Jq values than the normalization or DCPD method. Only for tests where the UC method underpredicted the crack extension by a very small value, J-R curves determined by the UC method were similar to those determined by the normalization or DCPD method.