April 2016

Journal

High voltage testing for the Majorana Demonstrator

By:
Abgrall, N.; Arnquist, I.; Efremenko, Yuri V; Galindo-Uribarri, Alfredo ; Green, Matthew P; Radford, David C; Shanks, Benjamin E; Varner Jr, Robert L; Wilkerson, John F; Yu, Chang-Hong ; Yumatov, V.
Journal Name:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Page Number:
83-90
Volume:
823
Issue Number:
n/a
Publication Date:
April 2016
View DOI Listing:
https://doi.org/10.1016/j.nima.2016.04.006

Abstract

The Majorana Collaboration is constructing the Majorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the Majorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during the Majorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.