July 2011

Journal

Global Evaluation of Prompt Dose Rates in ITER Using Hybrid Monte Carlo/Deterministic Techniques

By:
Ibrahim, A.; Sawan, M.; Mosher, Scott W; Evans, Thomas M; Peplow, Douglas E; Wilson, P.; Wagner, John C
Journal Name:
Fusion Science and Technology
Page Number:
676-680
Volume:
60
Issue Number:
2
Publication Date:
July 2011

Abstract

The hybrid Monte Carlo (MC)/deterministic techniques - Consistent Adjoint Driven Importance Sampling (CADIS) and Forward Weighted CADIS (FW-CADIS) - enable the full 3-D modeling of very large and complicated geometries. The ability of performing global MC calculations for nuclear parameters throughout the entire ITER reactor was demonstrated. The 2 m biological shield (bioshield) reduces the total prompt operational dose by six orders of magnitude. The divertor cryo-pump port results in a peaking factor of 120 in the prompt operational dose rate behind the bioshield by a factor of 47. The peak values of the prompt dose rates at the back surface of the bioshield were 240 uSv/hr and 94 uSv/hr corresponding to the regions behind the divertor cryo-pump port and the equatorial port, respectively.