January 2018

Journal

The detection of He in tungsten following ion implantation by laser-induced breakdown spectroscopy

By:
Shaw, Guinevere C; Bannister, Mark E; Biewer, Theodore M; Martin, Madhavi ; Meyer, Fred W; Wirth, Brian D
Journal Name:
Applied Surface Science
Page Number:
695-703
Volume:
427
Issue Number:
B
Publication Date:
January 2018
View DOI Listing:
https://doi.org/10.1016/j.apsusc.2017.08.180

Abstract

Laser-induced breakdown spectroscopy (LIBS) results are presented that provide depth-resolved identification of He implanted in polycrystalline tungsten (PC-W) targets by a 200 keV He+ ion beam, with a surface temperature of approximately 900 °C and a peak fluence of 1023 m−2. He retention, and the influence of He on deuterium and tritium recycling, permeation, and retention in PC-W plasma facing components are important questions for the divertor and plasma facing components in a fusion reactor, yet are difficult to quantify. The purpose of this work is to demonstrate the ability of LIBS to identify helium in tungsten; to investigate the sensitivity of laser parameters including, laser energy and gate delay, that directly influence the sensitivity and depth resolution of LIBS; and to perform a proof-of-principle experiment using LIBS to measure relative He intensities as a function of depth. The results presented demonstrate the potential not only to identify helium but also to develop a methodology to quantify gaseous impurity concentration in PC-W as a function of depth.