May 2011

Journal

PLACING ACETIC ACID REMOVAL INTO THE UREX plus PROCESS

By:
Mitchell, Jessica; Counce, Robert M; Watson, Jack; Spencer, Barry B; Del Cul, Guillermo D
Journal Name:
Nuclear Technology
Page Number:
422-429
Volume:
170
Issue Number:
3
Publication Date:
May 2011

Abstract

Recycle of nitric acid in the UREX+ process requires removal of acetic acid. An analysis of the effects of acetic acid in each process step indicates no step will be significantly affected by the concentrations expected. Thus, acetic acid removal can be placed after the last salts are removed, just before the nitric acid is recycled. Two promising removal options have been considered, solvent extraction and distillation. Distillation requires removal of most of the water before large fractions of acetic acid are removed. The process would be energy intensive and would involve the handling of extremely concentrated nitric acid; therefore, solvent extraction appears to be more attractive.