- By:
- Wagner, F.; Becoulet, A.; Budny, R.; Erckmann, V.; Farina, D.; Giruzzi, G.; Kamada, Y.; Kaye, A.; Koechl, F.; Lackner, K.; (Marushchenko, N.; Murakami, Masanori ; Oikawa, T.; Parail, V.; Park, J.
- Journal Name:
- Plasma Physics and Controlled Fusion
- Page Number:
- 124044
- Volume:
- 52
- Issue Number:
- 12
- Publication Date:
- December 2010
- View DOI Listing:
- https://doi.org/10.1088/0741-3335/52/12/124044
Abstract
This paper considers the heating mix of ITER for the two main scenarios. Presently, 73 MW of absorbed power are foreseen in the mix 20/33/20 for ECH, NBI and ICH. Given a sufficient edge stability, Q = 10-the goal of scenario 2-can be reached with 40MW power irrespective of the heating method but depends sensitively inter alia on the H-mode pedestal temperature, the density profile shape and on the characteristics of impurity transport. ICH preferentially heats the ions and would contribute specifically with Delta Q 0.5, and strong off-axis current drive (CD). The findings presented here are based on revised CD efficiencies gamma for ECCD and a detailed benchmark of several CD codes. With ECCD alone, the goals of scenario 4 can hardly be reached. Efficient off-axis CD is only possible with NBI. With beams, inductive discharges with f(ni) > 0.8 can be maintained for 3000 s. The conclusion of this study is that the present heating mix of ITER is appropriate. It provides the necessary actuators to induce in a flexible way the best possible scenarios. The development risks of NBI at 1 MeV can be reduced by operation at 0.85 MeV.