August 2011

Journal

On the heating mix of ITER

By:
Wagner, F.; Becoulet, A.; Budny, R.; Erckmann, V.; Farina, D.; Giruzzi, G.; Kamada, Y.; Kaye, A.; Koechl, F.; Lackner, K.; (Marushchenko, N.; Murakami, Masanori ; Oikawa, T.; Parail, V.; Park, J.
Journal Name:
Plasma Physics and Controlled Fusion
Page Number:
124044
Volume:
52
Issue Number:
12
Publication Date:
August 7, 2011
View DOI Listing:
https://doi.org/10.1088/0741-3335/52/12/124044

Abstract

This paper considers the heating mix of ITER for the two main scenarios. Presently, 73 MW of absorbed power are foreseen in the mix 20/33/20 for ECH, NBI and ICH. Given a sufficient edge stability, Q = 10-the goal of scenario 2-can be reached with 40MW power irrespective of the heating method but depends sensitively inter alia on the H-mode pedestal temperature, the density profile shape and on the characteristics of impurity transport. ICH preferentially heats the ions and would contribute specifically with Delta Q 0.5, and strong off-axis current drive (CD). The findings presented here are based on revised CD efficiencies gamma for ECCD and a detailed benchmark of several CD codes. With ECCD alone, the goals of scenario 4 can hardly be reached. Efficient off-axis CD is only possible with NBI. With beams, inductive discharges with f(ni) > 0.8 can be maintained for 3000 s. The conclusion of this study is that the present heating mix of ITER is appropriate. It provides the necessary actuators to induce in a flexible way the best possible scenarios. The development risks of NBI at 1 MeV can be reduced by operation at 0.85 MeV.