April 2009

Conference Paper

Estimated Limits on Uncontrolled Beam Losses of Heavy Ions for Allowing Hands-On Maintenance at an Exotic Beam Facility Linac

By:
Ronningen, Reginald M.; Bollen, Georg; Remec, Igor
Journal Name:
Nuclear Technology
Page Number:
670-675
Volume:
168
Issue Number:
3
Publication Date:
April 2009
Conference Name:
11th International Conference on Radiation Shielding and the 15th Topical Meeting of the Radiation Protection and Shielding Division
Conference Location:
Pine Mountain, Georgia, United States of America

Abstract

The purpose of the study is to obtain estimates of limits on uncontrolled beam losses of heavy ions for allowing hands-on maintenance at a heavy-ion linac for a rare isotope beam facility. Semiempirical formulas are used to estimate dose equivalent rates from activated accelerator components for 1 W/m uncontrolled losses of protons up to 1 GeV. The estimated dose rates after a 100-day irradiation time, 4-h postshutdown cooling time are compared to a hands-on maintenance limit of 1 mSv/h (100 mrem/h) at 30 cm. The transport codes PHITS and MCNP5 and activation code DCHAIN-SP 2001 are used to verify the estimate for proton losses and to obtain limits on heavy-ion beam losses that will satisfy the hands-on maintenance dose rate limit.