- By:
- See, Nathan D; Cetiner, Mustafa S; Betzler, Benjamin R
- Journal Name:
- Nuclear Science and Engineering
- Page Number:
- 1-20
- Volume:
- TBD
- Issue Number:
- TBD
- Publication Date:
- January 2022
- View DOI Listing:
- https://doi.org/10.1080/00295639.2021.2011571
Abstract
This paper will demonstrate the potential of modern design for additive manufacturing by using computational fluid dynamics with design optimization. The Transformational Challenge Reactor Instrumentation and Control (I&C) Team has specifically requested that an instrumentation plane be designed for monitoring of the core-coolant-flow average temperature within ±5°C of the core outlet average temperature. However, because of systemwide constraints, this design space is allotted a pressure drop of only 0.5 psi. A successful design optimization study is discussed along with the thought process leading to the successful conclusion of an I&C plane with an average temperature of 497.3°C and a standard deviation of 1.03°C, all while maintaining a 3.38-kPa (0.49-psi) pressure drop across the outlet plenum.