Publication Type
Journal
Journal Name
Physical Review Accelerators and Beams
Publication Date
Volume
28
Issue
8
Abstract
We propose a modified maximum-entropy (MENT) algorithm for six-dimensional phase space tomography. The algorithm uses particle sampling and low-dimensional density estimation to approximate large sets of high-dimensional integrals in the original MENT formulation. We implement this approach using Markov Chain Monte Carlo (MCMC) sampling techniques and demonstrate convergence of six-dimensional MENT on both synthetic and measured data.