- By:
- Ho, Alec; Westover, Andrew S; Browning, Katie L; Maslyn, Jacqueline; Parkinson, Dilworth; Sahore, Ritu ; Dudney, Nancy J; Balsara, Nitash
- Journal Name:
- ACS Energy Letters
- Page Number:
- 1120-1124
- Volume:
- 7
- Issue Number:
- 3
- Publication Date:
- February 2022
- View DOI Listing:
- https://doi.org/10.1021/acsenergylett.2c00255
Abstract
Here, we present a comparison of lithium metal films produced via rolling and thermal evaporation using synchrotron hard X-ray microtomography. In past studies of rolled lithium metal foils, a large number of C, O, and N impurities were found and identified as the key cause for failure in lithium metal cells. In this comparison, the X-ray tomography data show that the evaporated lithium metal films have an average impurity concentration of 19 particles/mm3 in comparison to 1350 particles/mm3 in the rolled lithium metal. An analysis of the inner substrate/lithium interface and outer lithium surface of the thermally evaporated film shows a much greater concentration of impurities at these interfaces, further emphasizing the importance of interface engineering in producing high-quality lithium metal batteries. We show that, if surface contamination can be avoided, it is possible to obtain lithium films with no impurities detectable by synchrotron hard X-ray tomography.