November 2021

Conference Paper

Impact of the Transformer Magnetizing Inductance on the Performance of the Dual-Active Bridge Converter

By:
Yin, Shiyuan ; Debnath, Suman ; Wojda, Rafal P; Marthi, Phani Ratna Vanamali ; Saeedifard, Maryam
Page Number:
1-7
Book Title:
2021 IEEE 22nd Workshop on Control and Modelling of Power Electronics (COMPEL)
Publication Date:
November 2021
Publisher Location:
IEEE, New Jersey, United States of America
Conference Name:
IEEE COMPEL
Conference Location:
Virtual, Tennessee, United States of America
Conference Sponsor:
IEEE
View DOI Listing:
https://doi.org/10.1109/COMPEL52922.2021.9645978

Abstract

The magnetizing inductance of the high-frequency transformer in the dual-active bridge (DAB) converter is usually assumed to be much larger than its leakage inductance, thereby the magnetizing current can be negligible. However, ignoring the magnetizing current will lead to an error in the DAB converter design process. This paper analyzes the operation and performance of the DAB converter for a general case in which the transformer magnetizing inductance is taken into consideration. The analysis shows that the magnetizing inductance impacts the soft-switching region, the power transfer capability, and the leakage inductor current. A simulation case study is provided to verify the analysis. A DAB converter prototype is built to experimentally validate the analysis as well.