XSDOSE - Functional Modules

XSDOSE is a code used in conjunction with XSDRNPM to compute the neutron and gamma flux and the resulting dose at various points outside a finite cylinder or sphere. It may also be used to compute the flux and/or dose at various points due to a finite rectangular surface source or a circular disc. The code assumes that the outgoing angular flux distribution on the rectangle, cylinder, sphere, or disc is independent of position and that the surrounding media is a void. The numerical technique employed in XSDOSE is suitable for points on, close to, or far from the source.


Return to SCALE Overview


User Feedback

Questions or comments can be sent to scalehelp@ornl.gov.