Contents:
Introduction
Effect of Radiant Barrier on Heating and Cooling Bills
Important Non-Energy Considerations
Installation Procedures
Appendix
Key to Abbreviations
Information Services
About This Fact Sheet
|
Installation Procedures
Most residential roofs provide some type of attic or airspace that can
accommodate an effective radiant barrier system. In new residential construction,
it is fairly easy to install a radiant barrier system. The following images show five
possible locations for the installation of an attic radiant barrier system.
Location 1 is a relatively new application, where the radiant barrier material
is attached directly to the underside of the roof deck.
Location 2 may offer advantages to the builder during construction of a new
house. Before the roof sheathing is applied, the radiant barrier is draped over the
rafters or trusses in a way that allows the product to droop 1-1/2 to 3 inches
between each rafter.
In Locations 3 and 4, the radiant barrier is attached to either the faces or
bottoms of the rafters or top chords of the roof trusses. Locations 3 and 4 may be
used with either new construction, or with retrofit of an existing house. With
either Location 2, 3 or 4, the space between the roof sheathing and the radiant
barrier provides a channel through which warm air can move freely, as shown in
Figure 2.
In Location 5, the radiant barrier is laid out on the attic floor over the top of
existing attic insulation. As discussed previously, this location is susceptible to
the effects of dust accumulation. This location is not appropriate when a large part
of the attic is used for storage, since the radiant barrier surface must be exposed to
the attic space. Also, kitchen and bathroom vents and recessed lights should not
be covered with the radiant barrier.
To obtain the best performance with radiant barriers installed in Locations 1
through 4, radiant barrier material should also be installed over the gable ends.
For attics that are open to the space over garages or carports, the radiant barrier
should extend eight feet or more into the garage or carport to achieve the same
effect as installing a radiant barrier on the gable ends. It is not necessary to cover
the gable ends with Location 5.
Radiant barriers that are reflective on one or both sides may be used with
any of these locations. However, if the radiant barrier is reflective on only one
side, the reflective side must face toward the main attic space for Locations 1 and
5. Since a surface facing downwards is less likely to have dust settle on it, it is
also recommended that the reflective side face downwards toward the main attic
space for Locations 2, 3, and 4.
Since proper attic venting is important to obtain the best performance of the
radiant barrier, some modification in the attic vents may be required to achieve
expected performance. Where no ridge or gable vents exist, it is recommended
that one or the other be installed. Always check existing ridge vent systems to
ensure that roofing paper is not blocking the vent opening, and check the soffit
vents to ensure that they have not been covered with insulation.
When installing a radiant barrier, care should be taken not to compress
existing insulation present in the attic. The effectiveness of the existing insulation
is dependent upon its thickness, so if it is compressed, its R-value is decreased.
For instance, an R-19 batt compressed to 3-1/2 inches (to top of 2X4 attic floor
joists) would now be approximately an R-13 batt.
Safety considerations
- The installer should wear proper clothing and equipment as recommended
by the radiant barrier manufacturer. Handling conventional insulation may
cause skin, eye, and respiratory system irritation. If in doubt about the
effects of the insulation, protective clothing, gloves, eye protection, and
breathing protection should be worn.
- Be especially careful with electrical wiring, particularly around junction
boxes and old wiring. Never staple through, near, or over electrical wiring.
Repair any obvious frayed or defective wiring in advance of radiant barrier
installation.
- Work in the attic only when temperatures are reasonable.
- Work with a partner. Not only does it make the job go faster, it also
means that you'll have assistance should a problem occur.
- If the attic is unfinished, watch where you walk. If you step in the wrong
place, you could fall through the ceiling. Step and stand only on the attic
joists or trusses or the center of a strong moveable working surface.
- Watch your head. In most attics, roofing nails penetrate through the
underside of the roof. A hard hat may be of some use.
- Make sure that the attic space is well ventilated and lighted.
- Do not cover any recessed lights or vents with radiant barrier material
(attic floor application).
Previous Section - Important Non-Energy Considerations
Next Section - Appendix
|