Hotbox Test R-value Database

Icynene Wall Systems

 

Summary Of Hotbox Test Data And Calculations

 

Test 1

Icynene wall with hat channels

Test 2

Icynene wall with XPS sheathing

Tests performed Winter 1997 click here for test specifics


click here for test specifics

Meter Chamber Air, ° F (t h)

99.9
99.7

Meter Air Speed, MPH

0.23
0.29

Meter Chamber Average Surface, ° F (t 1)

97.6
98.0

Climate Air, ° F (t c)

57.4
56.3

Climate Air Speed, MPH

1.49
2.43

Climate Side-Average Surface, ° F (t 2)

59.9
58.2

Panel Mean Temperature, ° F

78.8
78.1

Meter Chamber Energy Input, Btu/hr (Q h+Q f)

237.8
227.5

R-Value, hr ft 2 ° F/Btu (surface to surface)

8.97
11.38

R u-Value, (R ms air+R+R cs air) hr ft 2° F/Btu (air to air)

10.14
12.40

R ms air, hr ft 2°F/Btu (meter chamber air film resistant)

0.56
0.48

R cs air, hr ft 2°F/Btu (climate chamber air film resistant)

0.60
0.55