Hotbox Test R-value Database

Concrete Panel With Metal Connectors And Concrete Penetrations

 

Summary Of Hotbox Test Data And Calculations

Tests performed May 2001

 

Meter side air temperature (°F)

76.2

Meter side air velocity (MPH)

0.3

Meter side connector area temp (°F)

67.4

Meter side concrete penetration temperature (°F)

57.6

Meter side rebar area temperature (°F)

70.1

Meter side joint area temperature (°F)

0.0

Meter side concrete panel area temperature (°F)

69.1

Average meter side wall surface temperature (t1) (°F)

68.7

Climate side air temperature (tc) (°F)

15.8

Climate side air velocity (MPH)

2.9

Climate side connector area temp (°F)

19.3

Climate side concrete penetration area temperature (°F)

26.7

Climate side rebar area temperature (°F)

18.9

Climate side joint area temperature (°F)

--

Climate side concrete panel surface temperature (°F)

19.7

Average climate side wall surface temperature (°F)

19.9

Meter side center hole area temp (°F)

--

Panel mean temperature (°F)

44.3

Total measured energy into meter box (TMP) (Btu/hr )

685.6
Energy through meter box walls (Q mbox) (Btu/hr )
0.01
Energy Input (total energy through wall) (Q h +Q r ) (Btu/hr )
685.6

Clear wall R-value (R) (h ft² E F/Btu )

4.6

Meter side air film resist. (R ms air) (h ft² E F/Btu )

0.69

Climate side air film resist. (R cs air) (h ft² E F/Btu )

0.38

Ru-value, (R ms air +R + Rcs air) (h ft² E F/Btu )

5.6