Advanced Wall Systems

ORNL Home ASTM Testing BEP
Home
Related Sites Work With
Us
Advanced Wall
Systems Home

Hotbox Test R-value Database

FSEC - Florida Solar Energy Center

 

Summary Of Hot Box Test Data And Calculations

tests performed Fall 1997
Compressed R-11, no XPS
Compressed R-11, 1 in. XPS
Full Thickness R-11, no XPS
Full Thickness R-11, 0.5 in. XPS
R-13 Without XPS
Wall Symbol
FSEC1
FSEC2
FSEC3
FSEC4
FSEC5

Meter Sid Air Temp, °F (th)

100.6
100.5
100.2
100.6
99.7

Meter Side Air Velocity, MPH

1.3
1.3
1.3
1.3
1.3

Meter Side Stud Area Temp, °F

94.8
96.9
95.0
97.0
95.6
Meter Side Center of Cavity Temp, °F
98.8
99.5
97.8
98.7
97.7
Average Meter Side Wall Surface Temp, °F (t1)
98.5
99.3
97.7
98.6
97.5

Climate Side Air Temp, °F (tc)

52.9
57.3
58.5
60.3
55.1

Climate Side Air Velocity, MPH

2.0
2.3
2.1
2.3
1.5

Climate Side Stud Area Temp, °F

56.7
58.9
61.9
62.3
58.8

Climate Side Center Of Cavity Temp, °F

54.6
58.4
60.1
61.7
56.8

Average Climate Side Wall Surface Temp, °F (t2)

54.8
58.4
60.3
61.7
57.0

Panel Mean Temp, °F

767.7
78.9
79.0
80.2
77.2

Energy Input, Btu/hr (Q h+Q f)

308.3
178.4
244.1
178.5
240.3

Clear Wall R-value hr ft 2 °F/Btu

9.06
17.75
9.85
13.29
10.94

R u-Value, (R ms air+R+R cs air) hr ft 2°F/Btu (air to air)

9.91
15.59
10.97
14.52
12.04

R ms air, hr ft 2°F/Btu (meter chamber air film resistant)

0.45
0.42
0.66
0.71
0.61

R cs air, hr ft 2°F/Btu (climate chamber air film resistant)

0.40
0.42
0.58
0.52
0.51

Home

<<Back

 

 

 
©2004 Oak Ridge National Laboratory