Tests performed May 2001 |
|
Meter side air temperature (°F)
|
71.5 |
Meter side air velocity (MPH)
|
0.5 |
Meter side connector area temp (°F)
|
69.8 |
Meter side concrete penetration temperature (°F)
|
-- |
Meter side rebar area temperature (°F)
|
69.9 |
Meter side joint area temperature (°F)
|
69.7 |
Meter side concrete panel area temperature (°F)
|
69.9 |
Average meter side wall surface temperature (t1) (°F)
|
69.9 |
Climate side air temperature (tc) (°F)
|
5.5 |
Climate side air velocity (MPH)
|
2.8 |
Climate side connector area temp (°F)
|
4.4 |
Climate side concrete penetration area temperature (°F)
|
-- |
Climate side rebar area temperature (°F)
|
4.8 |
Climate side joint area temperature (°F)
|
42.9 |
Climate side concrete panel surface temperature (°F)
|
4.5 |
Average climate side wall surface temperature (°F)
|
4.5 |
Meter side center hole area temp (°F)
|
-- |
Panel mean temperature (°F)
|
32.7 |
Total measured energy into meter box (TMP) (Btu/hr )
|
163.7 |
Energy through meter box walls (Q mbox) (Btu/hr ) |
0.01 |
Energy Input (total energy through wall) (Q h +Q r ) (Btu/hr ) |
163.7 |
Clear wall R-value (R) (h ft² E F/Btu )
|
29.1 |
Meter side air film resist. (R ms air) (h ft² E F/Btu )
|
0.64 |
Climate side air film resist. (R cs air) (h ft² E F/Btu )
|
0.38 |
Ru-value, (R ms air +R + Rcs air) (h ft² E F/Btu )
|
30.1 |