Test 1 |
Test 2 |
Test 3 |
| Tests performed Summer 2002 |
click here for test specifics |
|
|
Total Hours
total length of time test wall was in chamber
|
411 |
387 |
355 |
C-TEMP
weighted average of surface and joint TC's, climate side (°F)
|
26.6 |
27.3 |
25.6 |
M-TEMP
weighted average of surface and joint TC's, meter side (°F)
|
67.6 |
75.8 |
75.8 |
|
24.9 |
28.3 |
26.2 |
|
63.4 |
75.2 |
74.3 |
MA-AIR-T
average of 36 air TC's, meter side (°F)
|
75.2 |
79.6 |
80.0 |
M-BAF-T
average of 24 baffle TC's, meter side (°F)
|
72.8 |
78.5 |
78.8 |
C-AIR-T
average of 48 air TC's, climate side (°F)
|
22.3 |
26.9 |
24.9 |
C-BAF-T
average of 36 baffle TC's, meter side (°F)
|
23.4 |
27.6 |
25.6 |
M-AIR-VC
air velocity, meter side (MPH)
|
0.40 |
0.46 |
0.45 |
C-AIR-VC
air velocity, climate side (MPH)
|
3.25 |
3.15 |
3.14 |
∆T
temperature difference across sample wall
|
41.0 |
48.5 |
50.2 |
T(mean)
mean temperature across sample wall
|
47.1 |
51.5 |
50.7 |
Qmb
energy exchange through meter box walls (Btu/hr)
|
-0.003 |
0.006 |
0.006 |
Qmb fl
meter box flanking loss, determined by calibrations
|
4.853 |
4.836 |
4.836 |
Qwall
calculated energy flow through specimen wall (Qwall - Qsurr)
|
649.9 |
307.1 |
331.0 |
Face-To-Face Rwall
surface to surface R-value of wall (hr*ft2*°F/Btu)
|
4.0 |
10.1 |
9.7 |
Air-To-Air Ru wall
overall R-value of sample wall (air-to-air), Rms air + Rwall + Rcs air (hr*ft2*°F/Btu)
|
5.2 |
11.0 |
10.7 |
Rms air
meter side air film resistance (hr*ft2*°F/Btu)
|
0.747 |
0.788 |
0.796 |
Rcs air
climate side air film resistance (hr*ft2*°F/Btu)
|
0.420 |
0.403 |
0.412 |