|
Publications
Laser Spectroscopy and
Chemical Microtechnology Group Recent Publications By Topic
Ultrafast
Laser Spectroscopy for Chemical Imaging:
Kesanli, B., K. Hong, K.A. Meyer, H.-J.
Im, and S. Dai, "Highly Efficient Solid State Neutron Scintillators
based on Hybrid Sol-gel Nanocomposite Materials," Appl. Phys.
Lett., 89, 214104 (2006).
Corrugated
Thin Diamond Foils for SNS H- Injection Stripping:
Spickermann, T., M.J. Borden, R.J. Macek,
R.W. Shaw, C.S. Feigerle, and I. Sugai, "Comparison of Carbon and
Corrugated Diamond Stripper Foils under Operational Conditions at the
Los Alamos PSR," Nucl. Instrum. Methods Phys. Resh. A, 590,
25-31 (2008).
Plum, M.A., J. Holmes, R.W. Shaw, and C.S.
Feigerle, "SNS Stripper Foil Development Program," Nucl.
Instrum. Methods Phys. Resh. A, 590, 43-46 (2008).
Shaw, R.W., A.D. Herr, C.S. Feigerle, R.I.
Cutler, C.J. Liaw, and Y.Y. Lee, "Thin diamond films for SNS H-
injection stripping," 2003 Particle Accelerator Conference (PAC2003),
Portland, OR, p. 617. For on-line extended PAC abstracts, see the JACoW
web site (www.jacow.org/).
Shaw, R.W., C.S. Feigerle, L.L. Wilson,
M.E. Peretich, R.N. Potter, V.A. Davis, and C.J. Liaw, "Corrugated
thin diamond foils for SNS H- Injection Stripping," 2005 Particle
Accelerator Conference (PAC05), Knoxville, TN, p. 2152.
Shaw, R.W., C.S. Feigerle, L.L. Wilson,
M.A. Plum, T. Spickermann, M.J. Borden, Y. Irie, I. Sugai, and A. Takagi,
"Spallation Neutron Source (SNS) Diamond Stripper Foil Development,"
2007 Particle Accelerator Conference (PAC2007), Albuquerque, NM, p.
620.
Shaw, R.W., M.A. Plum, L.L. Wilson, C.F.
Luck, A.G. McDermott, Y.-J. Chen, R.L. Coleman, D.M. Gardner, C.S. Feigerle,T.
Spickermann, M.J. Borden, "Diamond Stripper Foil Experience at
SNS and PSR," 2008 European Particle Accelerator Conference (EPAC2008),
Genoa, Italy, THPPO86.
Computational
Nanophotonics:
Li, Cuncheng, K.L. Shuford, M. Chen, E.J.
Lee, and S.O. Cho, "A Facile Polyol Route to Uniform Gold Octahedra
with Tailorable Size and Their Optical Properties," ACS Nano,
2, 1760 (2008).
Shuford, K.L., K.A. Meyer, C. Li, S.O.
Cho, W.B. Whitten, and R.W. Shaw, "Nanoscale Coupling Effects on
Single Particle Microscopy," Invited Paper, Proc. SPIE 7033,
7033I (2008).
Bok, H.-M., K.L. Shuford, S. Kim, and S.
Park, "Multipole Surface Plasmon Modes for a Colloidal Solution
of Nanoporous Gold Nanorods and Their Comparison to Smooth Gold Nanorods,"
Nano Lett., 8, 2265-2270 (2008).
Shuford, K.L., J. Lee, T.W. Odom, and G.C.
Schatz, "Optical Properties of Gold Pyramidal Shells," J.
Phys. Chem. C, 112, 6662-6666 (2008).
Kim, S., K.L. Shuford, H.-M. Bok, S.K.
Kim, and S. Park, "Intraparticle Surface Plasmon Coupling in One-Dimensional
Nanostructures," Nano Lett., 8, 800-804 (2008).
LI, C., K.L. Shuford, Q.H. Park, W. Cai,
Y. Li, E.J. Lee, and S.O. Cho, "High-Yield Synthesis of Single-Crystalline
Gold Nanooctahedra," Angew. Chem. Int. Ed., 46, 3264-3268
(2007).
Shuford, K.L., S.K. Gray, M.A. Ratner,
and G.C. Schatz, "Substrate Effects on Surface Plasmons in Single
Nanoholes," Chem. Phys. Lett. 435, 123-126 (2007).
Analytical Spectroscopy using
Entangled Photons:
Zhao, Z., K.A. Meyer, W.B. Whitten, and
R.W. Shaw, "Optical Absorption Measurements with Parametric Downconverted
Photons," Anal. Chem., 80, 7635-7638 (2008).
Zhao, Z., K.A. Meyer, W.B. Whitten, R.W.
Shaw, R.S. Bennink, and W.P. Grice, "Observation of Spectral Asymmetry
in cw-pumped type-II Spontaneous Parametric Down-conversion," Phys.
Rev. A, 77, 063828 (2008).
Micrometer Scale Ion Trap Mass Spectrometers:
Pau, S., W.B. Whitten, and J.M. Ramsey,
"Planar Geometry for Trapping and Separating Ions and Charged Particles,"
Anal. Chem., 79, 6857-6861 (2007).
Pau, S., C.S. Pai, Y.L. Low, J. Moxom,
P.T.A. Reilly, W.B. Whitten, and J.M. Ramsey, "Microfabricated
Quadrupole Ion Trap for Mass Spectrometer Applications," Phys.
Rev. Lett., 96, 120801 (2006).
Harris, W.A., P.T.A. Reilly, W.B. Whitten,
and J.M. Ramsey, "Transportable Real-time Single-particle Ion Trap
Mass Spectrometer," Rev. Sci. Instrum., 76, 064102 (2005).
Whitten, W.B., P.T.A. Reilly, and J.M.
Ramsey, "High-pressure Ion Trap Mass Spectrometry," Rapid.
Commun. Mass Spectrom., 18, 1749-1752 (2004).
Quantitative
Aerosol MALDI Mass Spectrometry:
Aerosol MALDI of Peptides and Proteins
in an Ion Trap Mass Spectrometer: Trapping, Resolution and Signal-to-noise,"
Intl J. Mass. Spectrom., 258, 113-119 (2006).
Harris, W.A., P.T.A. Reilly, and W.B. Whitten,
"MALDI of Individual Biomolecule-containing Airborne Particles
in an Ion Trap Mass Spectrometer," Anal. Chem., 77, 4042-4050
(2005).
Ultra-high-mass
Mass Spectrometry beyond 100 kDa:
Koizumi, H., W.B. Whitten, and P.T.A. Reilly,
"Real-time Trapping of Intact Singly-charged Bovine Serum Albumin
Proteins with a Big Frequency-adjusted Quadrupole Trap," XXXXXXXXXXX.
Mass Spectrometric Detection of
Hazardous Nanoparticles:
Harris, W.A., P.T.A. Reilly, and W.B. Whitten,
"Detection of Chemical Warfare-related species on Complex Aerosol
Particles Deposited on Surfaces using an Ion Trap Mass Spectrometer,"
Anal. Chem., 79, 2354-2358 (2007).
Miscellaneous:
Wasel, W., K. Kuwana, P.T.A. Reilly, and
K. Saito, "Experimental Characterization of the Role of Hydrogen
in CVD Synthesis of MWCNTs," Carbon, 45, 833-838 (2007).
Reilly, P.T. A. and W.B. Whitten, "The
Role of Free Radical Condensates in the Production of Carbon Nanotubes
during the Hydrocarbon CVD Process," Carbon, 44, 1653-1160
(2006).
Rodgers, R.P., P.T.A. Reilly, W.B. Whitten,
and J.M. Ramsey, "Real-time Observation of Metastable Polymeric
Species formed from Precursor Soot," Chem. Phys. Lett., 397, 324-328
(2004).
|