Re: 8200 & HSZ40
Ry,
Here is some additional information. I hope this helps with your
configuration problems. If you have any further questions, please feel free to
contact me. Quick question, what revision of the hsz40 firmware are you running?
These are the lines from the disks in our kernel config.
bus pza6 at pci4 slot 10 vector pzaintr
controller scsi10 at pza6 slot 0
device disk rz84 at scsi10 drive 672
device disk rz85 at scsi10 drive 680
THIS IS THE OUTPUT OF SHOW FROM HSZTERM.
HSZ_yel_wht_6_> show devices
Name Type Port Targ Lun Used by
------------------------------------------------------------------------------
DISK100 disk 1 0 0 M1
DISK120 disk 1 2 0 M2
DISK210 disk 2 1 0 M3
DISK230 disk 2 3 0 M4
DISK300 disk 3 0 0 M1
DISK320 disk 3 2 0 M2
DISK410 disk 4 1 0 M3
DISK430 disk 4 3 0 M4
DISK510 disk 5 1 0 D502
DISK530 disk 5 3 0 D503
HSZ_yel_wht_6_> show disks
Name Type Port Targ Lun Used by
------------------------------------------------------------------------------
DISK100 disk 1 0 0 M1
DISK120 disk 1 2 0 M2
DISK210 disk 2 1 0 M3
DISK230 disk 2 3 0 M4
DISK300 disk 3 0 0 M1
DISK320 disk 3 2 0 M2
DISK410 disk 4 1 0 M3
DISK430 disk 4 3 0 M4
DISK510 disk 5 1 0 D502
DISK530 disk 5 3 0 D503
HSZ_yel_wht_6_> show failedsets
Name Storageset Uses Used by
------------------------------------------------------------------------------
FAILEDSET failedset
Switches:
NOAUTOSPARE
HSZ_yel_wht_6_> show raidsets
No storagesets
HSZ_yel_wht_6_> show mirrorsets
Name Storageset Uses Used by
------------------------------------------------------------------------------
M1 mirrorset DISK100 S1
DISK300
M2 mirrorset DISK120 S2
DISK320
M3 mirrorset DISK210 S1
DISK410
M4 mirrorset DISK230 S2
DISK430
HSZ_yel_wht_6_> show ?
Your options are:
CDROMS
DEVICES
DISKS
FAILEDSETS
OPTICALS
OTHER_CONTROLLER
PASSTHROUGH
RAIDSETS
MIRRORSETS
SPARESETS
STORAGESETS
STRIPESETS
THIS_CONTROLLER
UNITS
Unit number or container name
HSZ_yel_wht_6_> show sparesets
Name Storageset Uses Used by
------------------------------------------------------------------------------
SPARESET spareset
HSZ_yel_wht_6_> show storagesets
Name Storageset Uses Used by
------------------------------------------------------------------------------
S1 stripeset M1 D500
M3
S2 stripeset M2 D400
M4
M1 mirrorset DISK100 S1
DISK300
M2 mirrorset DISK120 S2
DISK320
M3 mirrorset DISK210 S1
DISK410
M4 mirrorset DISK230 S2
DISK430
SPARESET spareset
FAILEDSET failedset
HSZ_yel_wht_6_> show stripesets
Name Storageset Uses Used by
------------------------------------------------------------------------------
S1 stripeset M1 D500
M3
S2 stripeset M2 D400
M4
HSZ_yel_wht_6_> show units
LUN Uses
--------------------------------------------------------------
D400 S2
D500 S1
D502 DISK510
D503 DISK530
HSZ_yel_wht_6_> show this_controller
Controller:
HSZ40 ZG55004015 Firmware V27Z-0, Hardware B02
Not configured for dual-redundancy
SCSI address 6
Time: NOT SET
Host port:
SCSI target(s) (4, 5), Preferred target(s) (5)
Cache:
32 megabyte write cache, version 2
Cache is GOOD
Battery is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
CACHE_POLICY = B
Host Functionality Mode = A
References: